Troubleshooting (OMAX Maxiem 1515): Difference between revisions

no edit summary
No edit summary
Line 64: Line 64:


If the clog is particularly stubborn and won't come free with a simple high pressure test you may need to run the 100-cycle sample file available in the OMAX software. This will turn the pump on and off 100 times in an attempt to dislodge any contaminants.
If the clog is particularly stubborn and won't come free with a simple high pressure test you may need to run the 100-cycle sample file available in the OMAX software. This will turn the pump on and off 100 times in an attempt to dislodge any contaminants.
== OMAX Layout Problems ==
=== Layout Post is complaining about offsets being on the wrong side ===
If ''all'' off the offsets appear to be on the wrong side, rather than just a few, it's likely you clicked on the end point of the path and not the start point. [https://youtu.be/iAQ17LCD8QM Watch this video] to learn more.
If only a few of the paths are highlighted as an error you should zoom in to check they are actually faulty. The error detection isn't perfect, and sometimes it picks up an error that doesn't actually exist.