COSHH - Cutwel - Fungicide Ultra

From Make In Salford

Storage Location

COSHH Cabinet - Morson Engine Room

Return this item to its storage place once you have finished using it. If it is empty, please let a member of technical staff know so more can be ordered.

Manufacturer's Information

Personal Protective Equipment

Nitrile Gloves
You must wear nitrile gloves when using this chemical.
Safety Glasses
You must wear safety glasses when using this chemical.
Visor may be required
If there is a risk of splashing a face shield or visor may be required.

Hazards

Keep out of reach of children
May cause an allergic skin reaction
Wear protective gloves when using this chemical, and other protective clothing if the circumstances require it. Prevent contact with skin, and wash immediately with plenty of soap and water in the event of contact.
Harmful if swallowed

Usage Information

  • The use of this coolant additive is controlled and should only be used when the coolant management process indicates it is a requirement. Record its use (including the ml used) in the Coolant Monitoring folder.
  • For a "shock" dose of a highly contaminated metalworking fluid use the following formula: Coolant Tank Volume x 0.5% = ml/litre.
  • For a maintenance "controlling" dose use the following formula: Coolant Tank Volume x 0.2% = ml/litre.
  • Add the fluid to the coolant at a point of high turbulence and circulate for at least 30 minutes to ensure it is mixed into the metalworking fluid properly.
  • If this additive is being used on the UMC-500 ensure that the through-spindle coolant pump is run for at least 30 minutes in addition and separately to to the normal coolant pump.

Dosage Amounts

  • Shock dose for the UMC-500, full coolant tank: 217 ml
  • Controlling dose for the UMC-500, full coolant tank: 87 ml
  • Shock dose for the ST-15Y, full coolant tank: 65 ml
  • Controlling dose for the ST-15Y, full coolant tank: 26 ml

More Information